45118 Key Specifications
- Max Operating Temperature
- 50°C
- Min Operating Temperature
- -18°C
- Height
- 133mm
- Width
- 70mm
Characteristics (datasheet)
- Catalogue / Ordering number
- 45118 ..........................Mini Thermo-Anemometer with Temperature
- Vane
- 1"(24mm) diameter
- Weight
- 3oz (95g)
- Power
- CR2032 Lithium battery
- ft/min (feet per minute) - Range
- 100 to 5500 ft/min
- ft/min (feet per minute) - Resolution
- 20ft/min
- ft/min (feet per minute) - Basic Accuracy
- ± (3%rdg + 40ft/min)
- m/s (meters per second) - Range
- 0.5 to 28m/s
- m/s (meters per second) - Resolution
- 0.1m/s
- m/s (meters per second) - Basic Accuracy
- ± (3%rdg + 0.2m/s)
- km/h (kilometers per hour - Range
- 1.8 to 100.6 km/h
- km/h (kilometers per hour - Resolution
- 0.7km/h
- km/h (kilometers per hour - Basic Accuracy
- ± (3%rdg + 1.4km/h)
- MPH (Miles per hour) - Range
- 1.1 to 62.5 MPH
- MPH (Miles per hour) - Resolution
- 0.2MPH
- MPH (Miles per hour) - Basic Accuracy
- ± (3%rdg + 0.4MPH)
- knots (nautical miles per hour) - Range
- 1.0 to 54.3 knots
- knots (nautical miles per hour) - Resolution
- 0.3knots
- knots (nautical miles per hour) - Basic Accuracy
- ± (3%rdg + 0.6knots)
- Beaufort Force - Range
- 1 to 17 BF
- Beaufort Force - Resolution
- 1 BF
- Beaufort Force - Basic Accuracy
- ±1
- Temperature - Range
- 0 to 122°F (-18 to 50°C)
- Temperature - Resolution
- 0.1°F/°C
- Temperature - Basic Accuracy
- ±1.8°F/±1°C
45118 Pinout & Package
- Mount
- External
The full pin configuration and pin descriptions are in the 45118 PDF datasheet above.
Other Flir parts
- 421502 — Handheld Test Equipment, LCD Display, 200°C to 1370°C, External Mount
- CMM-17-S — Digital Multimeters CMM-17 SOFTWARE
- 409992 — Instrument Protection and Storage Carrying Case
- 67500B — Digital Multimeters ELECTRODE ORP PRO
- 382213 — Desktop Power Supply, 3-Output, 30V, 3A, 220V AC Input
- 390GAS1 — Digital Panel Meters DPM BIG DIGIT CU
- PQ3470 — 3-Phase Graphical Power u0026 Harmonics Analyzer/Datalogger
- 380941-NIST — Clamp Multimeters u0026 Accessories MINI 200A AC/DC W/NIST
More Test Equipment
- FLUKE-700GA5 — 700GA5 Digi Positive Press Gauge 2bar 1/4 NPTin, Interface Type RS232 FLUKE 700
- 1685B — 60V 5A 300W Switching Bench Power Supply
- 34307A — THERMOCOUPLE KIT, 10 X J-TYPE THERMOCOUPLES, 72 IN LONG
- 33522B — Dual-Channel Arbitrary Waveform Generator, 30MHz Bandwidth, 250MS/s Sampling Rat...
- 3750 — KEITHLEY 3750 CONTROL CARD, MULTIFUNCTION
- 3706A-SNFP — KEITHLEY 3706A-SNFP Bench Digital Multimeter, Current, Volta...
- PG-100N-101R-WT — HANDHELD DIGITAL MANOMETER
- PG-100N-103R-WT — HANDHELD DIGITAL MANOMETER
45118 FAQ
What is 45118?
45118 is a Test Equipment from Flir. Environmental Test Equipment THERMO-ANEMOMETER.
Who manufactures 45118?
45118 is manufactured by Flir.
What is the operating temperature range of 45118?
45118 operates from -18°C to 50°C.
Where can I download the 45118 datasheet PDF?
The 45118 datasheet PDF (202 KB) can be downloaded free from this page using the Download PDF button.
Specifications
- Manufacturer
- Flir
- Category
- Test MeasurementTest Equipment
- File Size
- 202 KB
Ask AI Assistant
Ask questions about 45118 specifications
Click to ask a quick question:
Parameters
| Height | 133mm |
| Max Operating Temperature | 50°C |
| Min Operating Temperature | -18°C |
| Mount | External |
| Reach SVHC Compliant | Unknown |
| RoHS | Not Compliant |
| Weight | 1lb |
| Width | 70mm |