37106 Datasheet

BeldenBulk Wire Cable

Belden 37106 is a 6 AWG (84x25) stranded tinned copper lead wire with EPDM (ethylene propylene diene monomer) insulation. It is rated for 600 V under UL AWM styles 3340 and 3374 and operates from -55 °C to +150 °C. Suitable applications include Class 130(B), 155(F), and some 180(H) motor lead systems, high-temperature uses, and internal wiring of appliances.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

37106 Key Specifications

Max. current
153.6 Amps per Conductor at 30ºC
UL Voltage Rating
600 V (AWM 3340, AWM 3374)
Operating temperature
-55°C To +150°C (UL Temperature 150°C)
Conductor
6 AWG, 84x25 stranded Tinned Copper
Insulation material
EPDM - Ethylene Propylene Diene Monomer
Nominal conductor DCR
0.446 Ohm/1000ft
Nominal insulation thickness
0.088 in (2.2 mm)
Overall cable diameter
0.383 in (9.73 mm)

Characteristics (datasheet)

Conductor
6 AWG, 84x25 stranded Tinned Copper
Nominal conductor DCR
0.446 Ohm/1000ft
Max. current
153.6 Amps per Conductor at 30ºC
Insulation material
EPDM - Ethylene Propylene Diene Monomer
Nominal insulation thickness
0.088 in (2.2 mm)
Overall cable diameter
0.383 in (9.73 mm)
UL Voltage Rating
600 V (AWM 3340, AWM 3374)
Operating temperature
-55°C To +150°C (UL Temperature 150°C)

37106 Applications

  • Class 130(B) motor lead systems
  • Class 155(F) motor lead systems
  • some 180(H) motor lead systems
  • high temperature
  • internal wiring of appliances

Other Belden parts

  • 1332A — The Belden 1332A is a 20-pair 18AWG tinned copper fieldbus cable with polypropyl...
  • 77152 — The Belden 77152 is an ECOCABLE consisting of two 28 AWG stranded tinned copper...
  • 5859 — The Belden 5859 is a single-conductor 14 AWG hook-up wire featuring silver-plate...
  • 2142A — The Belden 2142A is a Category 6A Premise Horizontal cable designed for indoor a...
  • 45031 — The Belden 45031 is an XTRAGUARD 4 cable consisting of one pair of 18 AWG (16x30...
  • 89730 — The Belden 89730 is a 3-pair, 24 AWG stranded tinned copper conductor cable desi...
  • 7401W — The Belden 7401W is a high-flex MachFlex™ cable featuring a 2+1 conductor config...
  • 83304E — The Belden 83304E is a high-temperature, single-conductor electronic cable desig...

More Bulk Wire Cable

  • 28601A — Belden 28601A is a UL Type TC power and control cable with eight 18 AWG (7x26) b...
  • 50097TPE — The 50097TPE is a Belden As-Interface bus flat cable containing two 1.5 mm² stra...
  • 9912 — The Belden 9912 is a low-temperature plastic lead wire featuring a 12 AWG tinned...
  • 3112A — The Belden 3112A is a Type KX thermocouple cable containing a single pair of 20...
  • 78332 — The Belden 78332 is a 2-conductor 22 AWG tinned copper ECOCABLE with modified po...
  • 1218B — The Belden 1218B is an audio snake cable containing six 22 AWG tinned copper pai...
  • 8915 — The Belden 8915 is a low-temperature plastic lead wire featuring an 18 AWG solid...
  • 9981 — The Belden 9981 is a low-temperature plastic lead wire featuring an 18 AWG tinne...

37106 FAQ

What is 37106?

37106 is a Bulk Wire Cable from Belden. Belden 37106 is a 6 AWG (84x25) stranded tinned copper lead wire with EPDM (ethylene propylene diene monomer) insulation. It is rated for 600 V under UL AWM styles 3340 and 3374 and operates from -55 °C to +150 °C. Suitable applications include Class 130(B), 155(F), and some 180(H) motor lead systems, high-temperature uses, and internal wiring of appliances.

Who manufactures 37106?

37106 is manufactured by Belden.

Where can I download the 37106 datasheet PDF?

The 37106 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 37106 specifications

AI Powered

Click to ask a quick question:

Parameters

Conductor6 AWG, 84x25 stranded Tinned Copper
Insulation materialEPDM - Ethylene Propylene Diene Monomer
Max. current153.6 Amps per Conductor at 30ºC
Nominal conductor DCR0.446 Ohm/1000ft
Nominal insulation thickness0.088 in (2.2 mm)
Operating temperature-55°C To +150°C (UL Temperature 150°C)
Overall cable diameter0.383 in (9.73 mm)
UL Voltage Rating600 V (AWM 3340, AWM 3374)