3084A Datasheet
The Belden 3084A is a DeviceBus® communication cable designed for ODVA DeviceNet™ device-level communication in harsh industrial environments. It features a 2-pair construction with 22 AWG power and 24 AWG data stranded tinned copper conductors, insulated in PVC and foam PE, and protected by individual Beldfoil® and overall tinned copper braid shields. This cable is used for control, configuration, and data collection between industrial devices such as sensors, actuators, PLCs, and PCs in standard bus topologies.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
3084A Key Specifications
- Max Current (Data Pair)
- 4 Amps per Conductor at 30ºC
- Max Current (Power Pair)
- 6 Amps per Conductor at 30ºC
- Nom. Capacitance (Data)
- 12 pF/ft (39 pF/m)
- UL Voltage Rating
- 300 V (CMG, CL2), 600 V (AWM 20201)
- Voltage Rating
- 300 V (AWM I/II A)
- Operating Temperature
- -20°C to +60°C
- UL Temperature
- 60°C
- Bend Radius (Stationary / Installation Min.)
- 2.8 in (71 mm)
Characteristics (datasheet)
- Conductors
- Power Pair: 1 pair, 22 AWG, 19x34 TC (Tinned Copper); Data Pair: 1 pair, 24 AWG, 19x36 TC
- Insulation
- Power Pair(s): PVC (0.021 in thickness); Data Pair(s): PE - Polyethylene (Foam) (0.026 in thickness)
- Inner Shield
- Tape, Bi-Laminate (Alum+Poly), 100% coverage on both pairs
- Outer Shield
- Braid, Tinned Copper (TC), 65% coverage, with 22 AWG (19x34) TC drainwire
- Outer Jacket
- PVC - Polyvinyl Chloride, 0.032 in thickness, Nom. Diameter 0.280 in (7.11 mm)
- Nom. Characteristic Impedance (Data)
- 120 Ohm
- Nom. Capacitance (Data)
- 12 pF/ft (39 pF/m)
- Bulk Cable Weight
- 44 lbs/1000ft
Absolute Maximum Ratings
- UL Voltage Rating
- 300 V (CMG, CL2), 600 V (AWM 20201)
- Voltage Rating
- 300 V (AWM I/II A)
- UL Temperature
- 60°C
- Operating Temperature
- -20°C to +60°C
- Max Current (Power Pair)
- 6 Amps per Conductor at 30ºC
- Max Current (Data Pair)
- 4 Amps per Conductor at 30ºC
- Max Pull Tension
- 70.06 lbs (31.78 kg)
- Bend Radius (Stationary / Installation Min.)
- 2.8 in (71 mm)
3084A Applications
- ODVA device-level communication (DeviceNet) in harsh environments
- Control, configuration, and data collection between sensors and actuators
- Connecting higher level devices such as PLC and PC in industrial automation
- Bus topology networks
Other Belden parts
- 45373 — Belden 45373 is an XTRAGUARD 4 multi-pair cable built with 3 pairs of 18 AWG (16...
- 9406 — The Belden 9406 is an audio, control, and instrument cable featuring 22 AWG stra...
- 35193 — The Belden 35193 is an XTRAGUARD 3 cable with three 22 AWG (7x30) stranded tinne...
- 80009 — The Belden 80009 ECOFLEX PUR is a zero-halogen, 3-conductor 24 AWG tinned copper...
- 6017C — The Belden 6017C is a shielded communication and control cable consisting of 12...
- 79206 — The Belden 79206 is a high-flexibility, 9-conductor cable with 20 AWG tinned cop...
- 70001E — The Belden 70001E is a 300 V rated Profibus PA cable featuring a single pair of...
- 78192 — The Belden 78192 is a shielded multi-conductor cable (ECOCABLE) featuring 2 pair...
More Bulk Wire Cable
- 8138 — The Belden 8138 is an EIA RS-232/485 computer cable consisting of 8 pairs of 28...
- 3210 — The Belden 3210 is a single-conductor communication and control cable featuring...
- 5384C — The 5384C is a 4-conductor, 18 AWG tinned copper cable with PVC insulation, an o...
- 7035 — The Belden 7035 is a single-conductor hook-up wire featuring 14 AWG tinned coppe...
- 78345 — The Belden 78345 is a high-performance ECOCABLE featuring five 20 AWG stranded t...
- 9791 — The Belden 9791 is a low-capacitance computer EIA RS-232/423 cable designed for...
- 77115 — The Belden 77115 is a 12-conductor 20 AWG tinned copper ECOCABLE featuring mPPE...
- 78324 — The Belden 78324 is a 4-conductor, 24 AWG tinned copper ECOCABLE designed for da...
3084A FAQ
What is 3084A?
3084A is a Bulk Wire Cable from Belden. The Belden 3084A is a DeviceBus® communication cable designed for ODVA DeviceNet™ device-level communication in harsh industrial environments. It features a 2-pair construction with 22 AWG power and 24 AWG data stranded tinned copper conductors, insulated in PVC and foam PE, and protected by individual Beldfoil® and overall tinned copper braid shields. This cable is used for control, configuration, and data collection between industrial devices such as sensors, actuators, PLCs, and PCs in standard bus topologies.
Who manufactures 3084A?
3084A is manufactured by Belden.
Where can I download the 3084A datasheet PDF?
The 3084A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 3084A specifications
Click to ask a quick question:
Parameters
| Bend Radius (Stationary / Installation Min.) | 2.8 in (71 mm) |
| Bulk Cable Weight | 44 lbs/1000ft |
| Conductors | Power Pair: 1 pair, 22 AWG, 19x34 TC (Tinned Copper); Data Pair: 1 pair, 24 AWG, 19x36 TC |
| Inner Shield | Tape, Bi-Laminate (Alum+Poly), 100% coverage on both pairs |
| Insulation | Power Pair(s): PVC (0.021 in thickness); Data Pair(s): PE - Polyethylene (Foam) (0.026 in thickness) |
| Max Current (Data Pair) | 4 Amps per Conductor at 30ºC |
| Max Current (Power Pair) | 6 Amps per Conductor at 30ºC |
| Max Pull Tension | 70.06 lbs (31.78 kg) |
| Nom. Capacitance (Data) | 12 pF/ft (39 pF/m) |
| Nom. Characteristic Impedance (Data) | 120 Ohm |
| Operating Temperature | -20°C to +60°C |
| Outer Jacket | PVC - Polyvinyl Chloride, 0.032 in thickness, Nom. Diameter 0.280 in (7.11 mm) |
| Outer Shield | Braid, Tinned Copper (TC), 65% coverage, with 22 AWG (19x34) TC drainwire |
| UL Temperature | 60°C |
| UL Voltage Rating | 300 V (CMG, CL2), 600 V (AWM 20201) |
| Voltage Rating | 300 V (AWM I/II A) |