28327A Datasheet
The Belden 28327A is a UL Type TC (1277) power and control cable with seven 18 AWG bare copper conductors (7x26 stranding), PVC/nylon insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER) / 150 V (NPLF), 90 °C dry and wet, with an operating range of -30 °C to 90 °C wet/dry, and is intended for power and control applications up to 600 V including Class 1 Division 2 hazardous locations. The cable has a 0.360 in (9.14 mm) nominal overall diameter, includes a ripcord, and is sunlight resistant and suitable for direct burial.}
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
28327A Key Specifications
- Max Current
- 9.8 Amps per Conductor at 30ºC
- UL Voltage Rating
- 600 V (TC-ER), 150 V (NPLF)
- Operating Temperature
- -30°C to 90°C Wet/Dry
- UL Temperature
- 90°C Dry, 90°C Wet
- Conductors / Size / Stranding / Material
- 7 conductors, 18 AWG, 7x26, BC - Bare Copper
- Max Pull Tension
- 154 lbs (69.9 kg)
- Nominal Conductor DCR
- 6.7 Ohm/1000ft
- Overall Cable Diameter (Nominal)
- 0.360 in (9.14 mm)
Characteristics (datasheet)
- Conductors / Size / Stranding / Material
- 7 conductors, 18 AWG, 7x26, BC - Bare Copper
- Nominal Conductor DCR
- 6.7 Ohm/1000ft
- Max Current
- 9.8 Amps per Conductor at 30ºC
- UL Voltage Rating
- 600 V (TC-ER), 150 V (NPLF)
- UL Temperature
- 90°C Dry, 90°C Wet
- Operating Temperature
- -30°C to 90°C Wet/Dry
- Overall Cable Diameter (Nominal)
- 0.360 in (9.14 mm)
- Max Pull Tension
- 154 lbs (69.9 kg)
28327A Applications
- Power and Control Applications up to 600V
- Class 1 Division 2 Hazardous Locations
Other Belden parts
- 83752 — The Belden 83752 is a high-temperature, 2-conductor 14 AWG (7x22) tinned copper...
- 8216 — The Belden 8216 is a 50 Ohm RG-174 flexible coaxial cable designed for wireless...
- 9614 — The Belden 9614 is a computer EIA RS-232 cable designed for data transmission an...
- 5032C — The Belden 5032C is an XTRAGUARD 1 cable with two 18 AWG tinned copper conductor...
- 82504 — The Belden 82504 is a plenum-rated, computer EIA RS-232 cable designed for indoo...
- 45166 — Belden part 45166 is an XTRAGUARD 4 cable with 6 conductors of 18 AWG (16x30) ti...
- 83953 — The Belden 83953 is a Type KX thermocouple cable featuring a single pair of 16 A...
- 5322C — The 5322C is a 12-conductor, 20 AWG tinned copper cable with semi-rigid PVC insu...
More Bulk Wire Cable
- 78119 — The Belden 78119 is a 9-pair, 26 AWG stranded tinned copper ECOCABLE designed fo...
- 9976 — The Belden 9976 is a low-temperature plastic lead wire with a single 26 AWG soli...
- 23534D — Belden part 23534D is a Canadian Instrumentation Cable (TC-ACIC) rated 300 V wit...
- 8847MN — The Belden 8847MN is a SpaceMaker™ multi-conductor cable featuring 9 conductors...
- 8056 — The Belden 8056 is a 32 AWG solid bare copper magnet wire with PUR/NYL (polyuret...
- 83509 — The Belden 83509 is a high-temperature, chemical-resistant electronic cable desi...
- 83556 — The Belden 83556 is a high-temperature, 6-conductor 22 AWG tinned copper electro...
- 88241 — The Belden 88241 is a plenum-rated RG59 coaxial cable designed primarily for sta...
28327A FAQ
What is 28327A?
28327A is a Bulk Wire Cable from Belden. The Belden 28327A is a UL Type TC (1277) power and control cable with seven 18 AWG bare copper conductors (7x26 stranding), PVC/nylon insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER) / 150 V (NPLF), 90 °C dry and wet, with an operating range of -30 °C to 90 °C wet/dry, and is intended for power and control applications up to 600 V including Class 1 Division 2 hazardous locations. The cable has a 0.360 in (9.14 mm) nominal overall diameter, includes a ripcord, and is sunlight resistant and suitable for direct burial.}.
Who manufactures 28327A?
28327A is manufactured by Belden.
Where can I download the 28327A datasheet PDF?
The 28327A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 28327A specifications
Click to ask a quick question:
Parameters
| Conductors / Size / Stranding / Material | 7 conductors, 18 AWG, 7x26, BC - Bare Copper |
| Max Current | 9.8 Amps per Conductor at 30ºC |
| Max Pull Tension | 154 lbs (69.9 kg) |
| Nominal Conductor DCR | 6.7 Ohm/1000ft |
| Operating Temperature | -30°C to 90°C Wet/Dry |
| Overall Cable Diameter (Nominal) | 0.360 in (9.14 mm) |
| UL Temperature | 90°C Dry, 90°C Wet |
| UL Voltage Rating | 600 V (TC-ER), 150 V (NPLF) |