24515D Datasheet
The Belden 24515D is a 600 V Canadian Instrumentation Cable (TC-ACIC) with 12 pairs of 18 AWG stranded tinned copper conductors, XLPE insulation, individual and overall Beldfoil® shielding, a PVC inner jacket, aluminum interlock armor, and a black PVC outer jacket. It is rated for -40 °C to +105 °C dry / 90 °C wet operation and is intended for industrial control, raceways, cable trays, digital control, instruments, encoders, DCS, PLC, solenoids, valves, actuators, and positioners.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
24515D Key Specifications
- Voltage Rating
- 600 V
- Operating Temperature
- -40°C To +105°C Dry/90°C Wet
- Bend Radius Installation Min.
- 16.2 In
- Bulk Cable Weight
- 741 lbs/1000ft (1100 kg/km)
- Conductor
- 12 Pair 18 AWG 7x26 Tinned Copper
- Max. Pull Tension
- 200 Lbs.
- Nom. Conductor DCR
- 14.7 Ohm/1000ft (48.2 Ohm/km)
- Outer Jacket Nom. Diameter
- 1.353 in (34.37 mm)
Characteristics (datasheet)
- Voltage Rating
- 600 V
- Nom. Conductor DCR
- 14.7 Ohm/1000ft (48.2 Ohm/km)
- Operating Temperature
- -40°C To +105°C Dry/90°C Wet
- Bend Radius Installation Min.
- 16.2 In
- Max. Pull Tension
- 200 Lbs.
- Bulk Cable Weight
- 741 lbs/1000ft (1100 kg/km)
- Conductor
- 12 Pair 18 AWG 7x26 Tinned Copper
- Outer Jacket Nom. Diameter
- 1.353 in (34.37 mm)
24515D Applications
- Industrial Control
- Raceways Cable trays and ducts
- Digital Control
- Instruments (4-20ma, 0-10v, ...)
- low voltage digital control (24v, …)
- encoders
- control circuits
- distributed control system (DCS)
- programmable logic controller (PLC)
- Solenoids
- Valves
- Actuators
- Positioners
Other Belden parts
- 21632 — The Belden 21632 is a CSA TC-CIC 600 V tray cable with 34 conductors: thirty 10...
- 78193 — The Belden 78193 is a 3-pair 20 AWG tinned copper ECOCABLE with modified polyphe...
- 932795001 — HIRSCHMANN TEST AND MEASUREMENT 932795001 TEST LEAD KIT
- 6377 — The Belden 6377 is a communication and control cable consisting of 6 pairs of 22...
- 78340 — The Belden 78340 is a 10-conductor, 22 AWG stranded tinned copper ECOCABLE featu...
- 9222 — The Belden 9222 is a 50Ω triaxial RG-58A/U type cable featuring a 20 AWG strande...
- 1068A — The Belden 1068A is a 24-pair, 18 AWG bare copper instrumentation cable with PVC...
- 21639 — Belden 21639 is a CSA Tray Cable type TC-CIC rated 600 V, containing 41 conducto...
More Bulk Wire Cable
- 76501TS — The 76501TS is a MachFlex™ high-flexibility cable featuring two 26 AWG tinned co...
- 86410CY — The Belden 86410CY is an XTRAGUARD FLEX continuous flex data cable featuring 10...
- 80065 — The part 80065 is a 3-conductor 10 AWG tinned copper cable with MPPE insulation...
- 9964 — The Belden 9964 is a 4-conductor, 20 AWG tinned copper electronic cable with PVC...
- 6173 — The Belden 6173 is a heavy-duty Teck90 600V cable designed for CEC power and con...
- 8625MN — The Belden 8625MN is a SpaceMaker™ 5-conductor cable with 16AWG tinned copper co...
- 55092 — The Belden 55092 is a high-performance, 2-conductor, 24 AWG tinned copper shield...
- 9945 — The Belden 9945 is a multi-conductor computer EIA RS-232 cable featuring nine 22...
24515D FAQ
What is 24515D?
24515D is a Bulk Wire Cable from Belden. The Belden 24515D is a 600 V Canadian Instrumentation Cable (TC-ACIC) with 12 pairs of 18 AWG stranded tinned copper conductors, XLPE insulation, individual and overall Beldfoil® shielding, a PVC inner jacket, aluminum interlock armor, and a black PVC outer jacket. It is rated for -40 °C to +105 °C dry / 90 °C wet operation and is intended for industrial control, raceways, cable trays, digital control, instruments, encoders, DCS, PLC, solenoids, valves, actuators, and positioners.
Who manufactures 24515D?
24515D is manufactured by Belden.
Where can I download the 24515D datasheet PDF?
The 24515D datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 24515D specifications
Click to ask a quick question:
Parameters
| Bend Radius Installation Min. | 16.2 In |
| Bulk Cable Weight | 741 lbs/1000ft (1100 kg/km) |
| Conductor | 12 Pair 18 AWG 7x26 Tinned Copper |
| Max. Pull Tension | 200 Lbs. |
| Nom. Conductor DCR | 14.7 Ohm/1000ft (48.2 Ohm/km) |
| Operating Temperature | -40°C To +105°C Dry/90°C Wet |
| Outer Jacket Nom. Diameter | 1.353 in (34.37 mm) |
| Voltage Rating | 600 V |