The Belden 2118A is a single-pair fieldbus cable designed for harsh environment digital and serial two-way communication, commonly used in oil and gas extraction, petrochemical, and Profibus or Foundation FieldBus process automation. It features 18AWG tinned copper conductors with XLPO insulation, overall Beldfoil shielding, and a 600V-rated TPE outer jacket. This cable is built to withstand extreme temperatures, moisture, dust, oil exposure, and long-distance remote installations.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
2118A Key Specifications
- Max. Current
- 8.7 Amps per Conductor
- Nom. Capacitance Cond-to-Shield
- 22 pF/ft (72 pF/m)
- UL Voltage Rating
- 600 V
- Operating Temperature
- -40°C to +90°C
- Bulk Cable Weight
- 51 lbs/1000ft
- Max. Pull Tension
- 44.8 lbs (20.3 kg)
- Nom. Characteristic Impedance
- 100 Ohm
- Nom. Conductor DCR
- 7.06 Ohm/1000ft
Characteristics (datasheet)
- Nom. Conductor DCR
- 7.06 Ohm/1000ft
- Nom. Capacitance Cond-to-Shield
- 22 pF/ft (72 pF/m)
- Nom. Characteristic Impedance
- 100 Ohm
- Max. Current
- 8.7 Amps per Conductor
- UL Voltage Rating
- 600 V
- Operating Temperature
- -40°C to +90°C
- Max. Pull Tension
- 44.8 lbs (20.3 kg)
- Bulk Cable Weight
- 51 lbs/1000ft
2118A Applications
- Harsh environment digital and serial two-way communication
- Oil and gas extraction and refining sites
- Petrochemical
- Profibus process automation
- Foundation FieldBus process automation
- Extreme temperature environments
- Exposure to humidity/moisture, dust, and oil
- Remote locations long distance applications
Other Belden parts
- 35718 — Belden part 35718 is an 18 AWG stranded tinned copper lead wire with XLPO/XLPE t...
- 57602 — The Belden 57602 is a plenum-rated, shielded communication and control cable fea...
- 8428 — The Belden 8428 is a 2-conductor, 18 AWG stranded tinned copper microphone cable...
- 1306 — The Belden 1306 is a RW90 1000V, 2/0 AWG bare copper cable with XLPE insulation,...
- 7972A — The Belden 7972A is an Industrial Ethernet Category 6 cable featuring four bonde...
- 50064L — The Belden 50064L is an RS-485 cable consisting of four pairs of 20 AWG stranded...
- 78345 — The Belden 78345 is a high-performance ECOCABLE featuring five 20 AWG stranded t...
- 9823 — The Belden 9823 is a 2-conductor coaxial cable with 22 AWG stranded tinned coppe...
More Bulk Wire Cable
- 78143 — The Belden 78143 is a 3-conductor 20 AWG tinned copper ECOCABLE with modified po...
- 29731C — Belden 29731C is a three-conductor VFD power cable built with 3/0 AWG bare coppe...
- 32412 — The Belden 32412 is a rubber lead wire with 12 AWG tinned copper conductors (19x...
- 78015 — The Belden 78015 is a 5-pair 26 AWG ECOCABLE featuring tinned copper conductors...
- 5876 — The Belden 5876 is a single-conductor hook-up wire featuring a 20 AWG silver-pla...
- 77404W — The Belden 77404W is a MachFlex™ high-flex cable designed with 4+G conductor 14A...
- 8673 — The Belden 8673 is a 2-conductor, 12 AWG bare copper electronic cable with PVC i...
- 9984 — The Belden 9984 is a low-temperature plastic lead wire with a 24AWG (7x32) tinne...
2118A FAQ
What is 2118A?
2118A is a Bulk Wire Cable from Belden. The Belden 2118A is a single-pair fieldbus cable designed for harsh environment digital and serial two-way communication, commonly used in oil and gas extraction, petrochemical, and Profibus or Foundation FieldBus process automation. It features 18AWG tinned copper conductors with XLPO insulation, overall Beldfoil shielding, and a 600V-rated TPE outer jacket. This cable is built to withstand extreme temperatures, moisture, dust, oil exposure, and long-distance remote installations.
Who manufactures 2118A?
2118A is manufactured by Belden.
Where can I download the 2118A datasheet PDF?
The 2118A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 2118A specifications
Click to ask a quick question:
Parameters
| Bulk Cable Weight | 51 lbs/1000ft |
| Max. Current | 8.7 Amps per Conductor |
| Max. Pull Tension | 44.8 lbs (20.3 kg) |
| Nom. Capacitance Cond-to-Shield | 22 pF/ft (72 pF/m) |
| Nom. Characteristic Impedance | 100 Ohm |
| Nom. Conductor DCR | 7.06 Ohm/1000ft |
| Operating Temperature | -40°C to +90°C |
| UL Voltage Rating | 600 V |