2107A Datasheet
The Belden 2107A is a 24-pair 18 AWG tinned copper fieldbus cable with XLPO insulation, individual and overall Beldfoil shields, and a TPE outer jacket. It is designed for harsh environment digital and serial two-way communication, commonly used in oil and gas extraction, petrochemical plants, and Profibus or Foundation FieldBus process automation. It is built to withstand extreme temperatures, moisture, dust, oil exposure, and long-distance remote location applications.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
2107A Key Specifications
- Max. Current
- 5.4 Amps per Conductor
- Nom. Capacitance Cond-to-Cond
- 22 pF/ft (72 pF/m)
- UL Voltage Rating
- 300 V RMS
- Operating Temperature
- -40°C to 90°C (UL Temperature 90°C)
- Conductor
- 24 pairs, 18 AWG (7x26) TC - Tinned Copper
- Max. Pull Tension
- 1400 lbs (640 kg)
- Nom. Characteristic Impedence
- 100 Ohm
- Nom. Conductor DCR
- 5.86 Ohm/1000ft (19.2 Ohm/km)
Characteristics (datasheet)
- Conductor
- 24 pairs, 18 AWG (7x26) TC - Tinned Copper
- Nom. Characteristic Impedence
- 100 Ohm
- Nom. Conductor DCR
- 5.86 Ohm/1000ft (19.2 Ohm/km)
- Nom. Capacitance Cond-to-Cond
- 22 pF/ft (72 pF/m)
- Max. Current
- 5.4 Amps per Conductor
- UL Voltage Rating
- 300 V RMS
- Operating Temperature
- -40°C to 90°C (UL Temperature 90°C)
- Max. Pull Tension
- 1400 lbs (640 kg)
2107A Applications
- Harsh environment digital and serial two-way communication
- Oil and gas extraction and refining sites
- Petrochemical
- Profibus process automation
- Foundation FieldBus process automation
- Extreme temperature environments
- Exposure to humidity/moisture, dust, and oil
- Remote locations long distance applications
Other Belden parts
- 80026 — The Belden 80026 (Alpha Wire P/N 80026) is a zero-halogen, 12-conductor 20 AWG t...
- 9927 — The Belden 9927 is a computer EIA RS-232/423 low-capacitance cable featuring fou...
- 5680 — The Belden 5680 is a 10-conductor, 26 AWG tinned copper cable with semi-rigid PV...
- 80128 — The 80128 is an ECOFLEX PUR cable consisting of 20 conductors of 20 AWG tinned c...
- 78022 — The Belden/Alpha Wire 78022 is a 2-conductor 24 AWG tinned copper ECOCABLE with...
- 1131C — The Belden 1131C is a 1-pair 18 AWG tinned copper communication and control cabl...
- 5584C — The Belden 5584C is an XTRAGUARD 1 shielded multi-conductor cable featuring 19 c...
- 86318CY — The Belden 86318CY is an XTRAGUARD FLEX continuous flex data cable featuring 18...
More Bulk Wire Cable
- 84316 — The Belden 84316 is a commercial, non-QPL Mil-Spec coaxial cable with a 50 Ohm c...
- 8054 — The 8054 is a 28 AWG solid bare copper magnet wire with PUR/NYL insulation, desi...
- 85164 — The Belden 85164 is a high-temperature shielded electronic cable featuring four...
- 1065 — The Belden 1065 is a 5-conductor, 16 AWG tinned copper control cable with PVC in...
- 9512 — The Belden 9512 is a high-performance instrumentation cable containing two 22 AW...
- 9410 — The Belden 9410 is a high-performance instrumentation cable consisting of a sing...
- 77134 — The Belden 77134 is a 3-conductor 16 AWG tinned copper ECOCABLE with modified po...
- 8461 — The Belden 8461 is a 2-conductor, 18 AWG tinned copper electronic cable with PVC...
2107A FAQ
What is 2107A?
2107A is a Bulk Wire Cable from Belden. The Belden 2107A is a 24-pair 18 AWG tinned copper fieldbus cable with XLPO insulation, individual and overall Beldfoil shields, and a TPE outer jacket. It is designed for harsh environment digital and serial two-way communication, commonly used in oil and gas extraction, petrochemical plants, and Profibus or Foundation FieldBus process automation. It is built to withstand extreme temperatures, moisture, dust, oil exposure, and long-distance remote location applications.
Who manufactures 2107A?
2107A is manufactured by Belden.
Where can I download the 2107A datasheet PDF?
The 2107A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 2107A specifications
Click to ask a quick question:
Parameters
| Conductor | 24 pairs, 18 AWG (7x26) TC - Tinned Copper |
| Max. Current | 5.4 Amps per Conductor |
| Max. Pull Tension | 1400 lbs (640 kg) |
| Nom. Capacitance Cond-to-Cond | 22 pF/ft (72 pF/m) |
| Nom. Characteristic Impedence | 100 Ohm |
| Nom. Conductor DCR | 5.86 Ohm/1000ft (19.2 Ohm/km) |
| Operating Temperature | -40°C to 90°C (UL Temperature 90°C) |
| UL Voltage Rating | 300 V RMS |