1529A Datasheet
The Belden 1529A is a 300V UL-rated instrumentation cable consisting of three 18 AWG pairs and one 22 AWG bare copper comm wire with PVC insulation, an overall Beldfoil shield, and a black PVC outer jacket. It is rated for an operating temperature range of -30°C to +105°C and offers sunlight and burial resistance for indoor/outdoor use. This cable is designed for use in industrial control systems, DCS, PLCs, encoders, and low-voltage digital control circuits driving solenoids, valves, and actuators.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
1529A Key Specifications
- Max current
- 3.5 Amps per Conductor at 25ºC
- Voltage rating
- 300 V (CMG, PLTC, UL AWM 2464)
- Operating temperature
- -30°C to +105°C (UL Temperature: 105°C)
- Bulk cable weight
- 94 lbs/1000ft
- Conductor configuration
- 3 pairs 18 AWG (7x26) + 1 comm wire 22 AWG (7x30) Bare Copper (BC)
- Maximum pull tension
- 157 lbs (71.2 kg)
- Minimum bend radius
- 4.4 in (110 mm) stationary / installation
- Nominal overall diameter
- 0.450 in (11.4 mm)
Characteristics (datasheet)
- Conductor configuration
- 3 pairs 18 AWG (7x26) + 1 comm wire 22 AWG (7x30) Bare Copper (BC)
- Nominal overall diameter
- 0.450 in (11.4 mm)
- Voltage rating
- 300 V (CMG, PLTC, UL AWM 2464)
- Max current
- 3.5 Amps per Conductor at 25ºC
- Operating temperature
- -30°C to +105°C (UL Temperature: 105°C)
- Minimum bend radius
- 4.4 in (110 mm) stationary / installation
- Maximum pull tension
- 157 lbs (71.2 kg)
- Bulk cable weight
- 94 lbs/1000ft
1529A Applications
- Industrial control
- Raceways, cable trays and ducts
- Digital control
- Instruments (4-20ma, 0-10v)
- Low voltage digital control (24v)
- Encoders
- Control circuits
- Distributed control system (DCS)
- Programmable logic controller (PLC)
- Solenoids, valves, actuators, positioners
Other Belden parts
- 7439W — The Belden 7439W is a high-flex MachFlex cable featuring 8+1 conductors of 14AWG...
- 2254 — The Belden 2254 is a communication and control cable consisting of two 22 AWG ti...
- 5039C — The Belden 5039C is an XTRAGUARD 1 multi-conductor cable with 9 pairs of 18 AWG...
- 5176C — The Belden 5176C is a 6-conductor, 16 AWG stranded tinned copper cable with PVC...
- 70257PU — The Belden 70257PU is a highly flexible, halogen-free, and flame-retardant PUR s...
- 77009 — The Belden 77009 is a 5-conductor, 22 AWG tinned copper cable with modified poly...
- 29544 — Belden 29544 is a flexible 2000 V VFD motor supply cable with three 1/0 AWG tinn...
- 78129 — The Belden 78129 is a 9-pair, 24 AWG tinned copper conductor cable with modified...
More Bulk Wire Cable
- 77112 — The Belden 77112 is a 5-conductor, 22 AWG tinned copper ECOCABLE with MPPE insul...
- 5355C — The Belden 5355C is a 27-pair, 20 AWG tinned copper cable with semi-rigid PVC in...
- 77053 — The Belden 77053 is a 3-conductor 28 AWG tinned copper control cable with mPPE i...
- 9493 — The Belden 9493 is a high-performance instrumentation cable featuring a single 1...
- 6179 — The Belden 6179 is a heavy-duty Teck90 1000V cable featuring four 3/0 AWG bare c...
- 79126 — The Belden 79126 is a high-flexibility, shielded multi-conductor cable (3-conduc...
- 5139C — The Belden 5139C is a nine-pair, 18 AWG tinned copper conductor cable with PVC i...
- 9992 — The Belden 9992 is an audio, control, and instrument cable featuring 9 individua...
1529A FAQ
What is 1529A?
1529A is a Bulk Wire Cable from Belden. The Belden 1529A is a 300V UL-rated instrumentation cable consisting of three 18 AWG pairs and one 22 AWG bare copper comm wire with PVC insulation, an overall Beldfoil shield, and a black PVC outer jacket. It is rated for an operating temperature range of -30°C to +105°C and offers sunlight and burial resistance for indoor/outdoor use. This cable is designed for use in industrial control systems, DCS, PLCs, encoders, and low-voltage digital control circuits driving solenoids, valves, and actuators.
Who manufactures 1529A?
1529A is manufactured by Belden.
Where can I download the 1529A datasheet PDF?
The 1529A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 1529A specifications
Click to ask a quick question:
Parameters
| Bulk cable weight | 94 lbs/1000ft |
| Conductor configuration | 3 pairs 18 AWG (7x26) + 1 comm wire 22 AWG (7x30) Bare Copper (BC) |
| Max current | 3.5 Amps per Conductor at 25ºC |
| Maximum pull tension | 157 lbs (71.2 kg) |
| Minimum bend radius | 4.4 in (110 mm) stationary / installation |
| Nominal overall diameter | 0.450 in (11.4 mm) |
| Operating temperature | -30°C to +105°C (UL Temperature: 105°C) |
| Voltage rating | 300 V (CMG, PLTC, UL AWM 2464) |